Model
KD7405AWH
Detection sensitivity 1
Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia.× 2 mm long
X-ray output
Tube voltage 25 to 60 kV, tube current 0.3 to 7.0 mA, output 7.5 to 210 W
Safety
X-ray leakage maximum 1μSv/h or less, prevention of x-ray leakage by safety devices
Display
15-inch color TFT LCD (unified image monitoring screen and operation screen)
Operation method
Touch panel (with touch buzzer)
Product size 2
Maximum width 240 mm, maximum height 120 mm (see drawing for detection area)
Belt width
270 mm
Masking function
Equipped as standard
Missing product detection function
Equipped as standard
Clip check function
Equipped as standard
Preset memory
Maximum 100
Belt speed 3 /
Maximum product weight 4
5 to 60 m/min, maximum 5 kg
61 to 90 m/min, maximum 2 kg
5 to 40 m/min, maximum 10 kg (optional)
Power requirements 5, 6, 7
100 to 120 or 200 to 240 Vac, single phase, 50/60 Hz, 1.0 kVA, rush current 80 A (typ.) (5 ms or less)
Mass
210 kg
Environmental conditions 8
Temperature: 0º to 35ºC (0º to 40ºC with optional air conditioner), relative humidity: 30% to 85%, non-condensing
Protection class
Conveyor IP66, other parts IP40, tool free belt removal
Exterior
Stainless steel (SUS304)
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. 2: The entrance and exit may require covers depending on the length of a product. 3: Variable depending on Product No. 4: Sum total of product weight on the conveyor. 5: Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. 6: Allowable power fluctuation range is ± 10%. 7: Installing the air-conditioner option changes the displayed power consumption. 8: The air-conditioner option may be required depending on the operating environment. Note: The noise level of x-ray inspection systems is 77 dB(A).
Detection Areas
A variety of models is available for a wide range of products. For details of detection areas, please submit an online inquiry form.

Model
Detection area
KD7405AWH/ADWH
KD7405BWH/BDWH
rentgen
For Packaged Products
KD7416AWH/ADWH
KD7416BWH/BDWH
rentgen
For Packaged Products
KD7417BWH
rentgen
For Packaged Products
KD7405ABWH
KD7416ABWH

rentgen
For Bulk Flow

of Unpacked Fresh Food

KD7405ACWH
KD7416ACWH

rentgen
For Lightweight Products

and Those in Small Bags